PAH 20-75 Specifications

MODEL PAH 20-75
High Inlet Temperature Air Dryers
- Cools...accepts high temperature air to 180°F, 82°C directly
from your air compressor...no separate aftercooler and separator
required
- Dries...removes moisture...eliminates troublesome water from
downstream air lines and equipment
- Cleans...an integral 3 micron filter removes solid contaminants
and 60% of oil aerosols (for virtually oil free air, high efficiency
oil removal filters are available)
- CSA Certified - 115V models
- CFC FREE - Uses minimum amount of environmentally acceptable
refrigerant
|
Model
|
PAH20x
|
PAH25x
|
PAH35x
|
PAH50x
|
PAH75x
|
|
Rated Flow (scfm)
1
|
25
|
31
|
43
|
61
|
92
|
|
Voltages (V/ph/Hz)
|
115/1/60
230/1/50
|
115/1/60
230/1/50
|
115/1/60
230/1/50
|
115/1/60
230/1/50
|
115/1/60
230/1/50
|
|
Power (kW)
2
|
0.7/0.6
|
0.7/0.6
|
0.7/0.6
|
1.4/1.1
|
1.4/1.1
|
|
Connection (in)
3
|
1/2" NPT
|
1/2" NPT
|
1/2" NPT
|
3/4" NPT
|
3/4" NPT
|
|
Height (in)
|
28
|
28
|
28
|
37
|
37
|
|
Width (in)
|
10
|
10
|
10
|
20
|
20
|
|
Depth (in)
|
13
|
13
|
13
|
17
|
17
|
|
Weight (lb)
|
79
|
80
|
81
|
150
|
155
|
x Standard 3 micron filter.
(1) Rated Flow Capacity - Conditions for rating dryers
are in accordance with CAGI (Compressed Air and Gas Institute) Standard
ADF 100: Refrigeration Compressed Air Dryers - Methods for Testing and
Rating. Conditions for rating above dryers are: compressed air at dryer
inlet: 100 psig (7 kgf/cm2) and 100°F (38°C); operating on
60 Hz power supply with aftercooler upstream. Outlet pressure dew point
at rated conditions is 38°F (3°C) and pressure drop is less than 5 psi
(0.34 kgf/cm2.
(2) At 35°F (2°C) evaporator and 100°F (38°C) ambient.
(3)NPT and BSP connections available.
Note: Maximum operating pressure: 175psig (12.3 kgf/cm2;
Maximum operating temperature: 180°F (82°C).
|